Parametric Shading and Daylight Design 2018 - TEST

Building Physics II - Parametric Shading and Daylight Design 2018 - PSDD18

TEST 31.10.2018

The test consists in complete the provided parametric and analysis file and perform Daylight Factor analysis to find a result of average 2% using three different  variations of window and shading size.
One of the two window sizes is given, the other should be changed together with the size of the shading device to get 3 variations all as much as possible close to the  result of average 2% of Daylight Factor.
The results should be written in the Panel component present in the files. The window and shading sizes and mDF should be written for all the 3 variations.
Are provided the Rhinoceros file Room.3dm the same for all the students and the Grasshopper file different for each student. The Grasshopper files are all the same (same difficulty level for all the students) except that the fixed size of the window change and is different for all the students.
Each students download the Room.3dm file and from the following list the file .gh with his/her name (each file contain the name of the students so it is not possible to use the file of other students).
The completed exercise should be sent by email to francesco.deluca@ttu.ee no later than 18.00 today 31.10.2018.

File for the 3D room in Rhinoceros


Files for the parametric Daylight Factor analysis in Grasshopper